ESP cables


Liwan Oil Tools supply power cable and motor lead extension cables in a wide range of sizes and construction types to be compatible with the most extreme downhole conditions.  

QYPN 205esp-cables.jpg
Polypropylene insulation with a rubber nitrile jacket. Operating temperature rating up to 205°F/ 96°C. Voltage rating of 3KV, 5KV, or 6 KV. Interlocking and preformed steel tape are used separately for Round or Flat Cable configuration.
 
QYPL225
Polypropylene insulation with a lead sheeth jacket. Operating temperature rating up to 225°F/ 107°C. Voltage rating of 3KV, 5KV, or 6 KV. Interlocking and preformed steel tape are used separately for Round or Flat Cable configuration.
 
QYEN285
EPDM insulation with a choice of nitrile rubber or EPDM jacket. Operating temperature rating up to 385°F / 140°C. Voltage rating of 3KV, 5KV, or 6 KV. Interlocking and preformed steel tape are used separately for Round or Flat Cable configuration.
 
QYEE300
EPDM insulation with EPDM jacket. Operating temperature rating up to 300°F / 149°C. Voltage rating of 3KV, 5 KV and 6KV. Interlocking and preformed steel tape are used separately for Round or Flat Cable configuration.
 
QYEE400
EPDM insulation with EPDM jacket. Operating temperature rating up to 400°F / 204°C. Voltage rating of 3KV, 5 KV and 6KV. Interlocking and preformed steel tape are used separately for Round or Flat Cable configuration.
 
QYEL450
EPDM insulation with lead jacket. Operating temperature rating up to 450°F / 232°C. Voltage rating of 3KV, 5 KV and 6KV. Interlocking and preformed steel tape are used separately for Round or Flat Cable configuration.
 
 
Motor Lead Extension Cable (MLE)
 
QYKEN
Polyimide film plus EPDM as insulation, NBR for jacket, Tape or Nylon Braid, preformed steel tape - Flat Cable . Operating temperature rating up to 285°F / 140°C. Voltage rating of 4KV, 6KV.

QYKEE
Polyimide film plus EPDM as insulation, EPDM for jacket, Tape or Nylon Braid, preformed steel tape - Flat Cable. Operating temperature rating up to 400°F / 204°C. Voltage rating of 4KV, 6KV.
 
QYKEL
Polyimide film plus improved EPDM as insulation, Lead sheath for jacket, bedding  layer, preformed steel tape - Flat Cable. Operating temperature rating up to 450°F / 232°C. Voltage rating of 4KV, 6KV.
 
Cable Armor Configurations
 
To provide the best protection available, we provides Galvanized Steel Armor, optional Armors are available for extra protection. These include Monel and Stainless Steel.
 
Round Cable Armor
Round cable can be protected with several types of interlocked armor.
  • Standard Galvanized Steel with thickness of .020",and heavy galvanized armor protection 0.025”
  • Stainless Steel with thickness of .020"
  • Monel 400 with thickness of .015"
 
 
Flat Cable Armor
Flat cable can be protected with several types of armors.
  • Standard Galvanized Steel with thickness of .020"
  • Stainless Steel with thickness of .020"
  • Monel 400 with thickness of .015"